Netkofire favicon 200x200
Skip to content

About Us

Netko Fire, Alanya and its surroundings fire detection and fire alarm systems It is an expert brand that offers exploration, project planning, installation, commissioning and periodic maintenance services in its field. It caters to buildings of various sizes, including hotels, shopping malls, residential complexes, hospitals, educational institutions and industrial facilities. EN54, TSE and CE We provide solutions that comply with standards.
By combining our experience in the field with the right project design, quality equipment selection and regular maintenance discipline, early warning, rapid evacuation And continuous operational security We secure your goals. We provide end-to-end services, from addressable and conventional fire detection architectures to gas detection, emergency routing, and emergency lighting systems; we can integrate with building automation (BMS), CCTV, public address, and other low-current infrastructures.

Our Services

Addressable Fire Detection and Alarm Systems

Netko Fire, Alanya and its surroundings addressable fire detection systems with hotel, shopping mall, hospital, educational institution, industrial facility and residence projects EN54-2/EN54-4 offers scalable and regulatory-compliant solutions that comply with industry standards. From discovery to project planning, loop-based from architectural design to device selection, from cabling infrastructure fire alarm panel programming and put in to use We provide end-to-end service from start to finish. We provide pinpoint fault/fire location through addressable detectors, buttons, sirens, flashers and monitoring modules. fast addressing with reports; BMS, CCTV and emergency announcement By integrating with subsystems such as early warning, safe evacuation and uninterrupted operation We guarantee your goals. Project delivery includes testing/commissioning, acceptance reports, device labeling, as-built documentation and user training. comprehensive we provide a package.

Conventional Fire Alarm Systems (Economical and Reliable)

For small and medium-sized workplaces, warehouses, sites and boutique hotels conventional fire alarm systemsis a cost-effective and quickly deployable solution. As Netko Fire, it uses zone-based architecture. smoke and heat detectors, manual buttons, interior/exterior siren-flashers and the system consisting of power units, TSE and EN54 We design according to your requirements. We perform zone planning based on escape routes, risk classes and types of space use; we take into account cabling sections, voltage drop, battery redundancy and fire scenario We include the requirements in the technical specifications. For all zones before delivery. smoke/heat test, short circuit/earth leakage control and reporting function tests We implement it; we provide the user with basic maintenance and alarm management training. From the conventional structure Switch to addressable or gas detection When expansion with additional modules is required, we build the project in a forward-looking, scalable architecture.

Fire Alarm Maintenance, Testing and Periodic Inspection Services

Continuity in fire safety, periodic maintenance and recorded testing processes. Netko Fire, addressable and conventional fire alarm systems Monthly/3-monthly/6-monthly/annual maintenance plans for, detector calibration and sensitivity tests, battery measurement and replacement, loop/zone continuity check, siren-strobe sound/light level verification and button function tests Panel software/update, analysis of event logs, review of line/alarm scenarios and legal regulations (EN54, Regulation on the Protection of Buildings from Fire) detailed information for compliance maintenance report And logbook We produce. 24/7 fault reporting line, SLA response times, spare equipment management and critical areas proactive parts replacement We aim to keep systems running at all times. For multi-location facilities central maintenance schedule And digital reporting We reduce the operational burden by providing support.

Why Should You Choose Us?

EN54 Compliant Engineering, Correct Project Design

Netko Fire, Alanya and its surroundings EN54 standards fully compatible fire detection and fire alarm systems During the exploration phase, by analyzing the use of space, risk classes, escape routes and the electrical and mechanical infrastructure of the facility addressed or conventional We design the architecture correctly. Loop/zone planning, cable cross-section and voltage drop calculations, siren-flasher levels, power redundancy (battery) and fire scenario Integration requirements with systems such as BMS, CCTV and emergency announcement are calculated step by step and incorporated into the project. This way, your business early warning, rapid evacuation And uninterrupted operation objectives are secured with technical data.

End-to-End Service: Discovery, Installation, Commissioning

We don't just supply devices; end-to-end solution We offer. After the field survey technical specifications and drawings are prepared, our installation team completes the installation and wiring in accordance with the project discipline. Panel programming, device labeling, testing & commissioning and official acceptance processes. User training, emergency scenario exercises and delivery as-built Sustainability is also ensured on the business side of the system through documentation. Post-delivery SLA support, spare parts management, and warranty processes are managed through a single channel.

Continuity with Periodic Maintenance and Rapid Intervention

Fire safety is not a “set it and forget it” job. Netko Fire maintenance programs, monthly/3-monthly/6-monthly/annual control for addressed and conventional systems, detector calibration, battery health, loop/zone continuity test, button and siren-flasher function tests, software updates and log analysis Includes maintenance reports and logbook with EN54 and Regulation on the Protection of Buildings from Fire Compliance is recorded. Thanks to the 24/7 fault reporting line, rapid access to the field and critical parts stock management, hotel, shopping mall and industrial facility operations minimum interruption continues with.

Local Experience, Transparent Pricing

We have acquired a wide range of facilities in the Alanya/Antalya region. local field experience, ensures faster and more accurate project progress. A clear scope and timeline after discovery and transparent pricing We share and avoid unnecessary equipment costs. We establish a modular infrastructure for growing needs, transition from conventional to addressableWe facilitate the integration of gas detection and emergency guidance. This way, return on investment increases, maintenance costs decrease, and your systems remain ready for future needs.

Feedback from Our Customers

What We Have Prepared For You

Contact us

Contact Form

Name and Surname

Frequently Asked Questions

What is the difference between addressable fire detection and conventional fire alarm systems?

Addressable fire detection In systems, each detector, module and button has a unique address; fire panel It shows the exact location of the incident and shortens the response time. Conventional fire alarm systems It works with a zone logic; you can see which area the alarm is coming from, but it can't be differentiated by device. In complex structures like hotels, shopping malls, or industrial facilities in Alanya, addressable system is generally a more secure and manageable solution; for small/medium businesses conventional architecture can be an economical choice.

Netko Fire, Alanya and surrounding areas on-site exploration, risk analysis and EN54 Provides focused technical project services. The building's intended use, escape routes, cabling routes, and power infrastructure are evaluated; addressed or conventional The architecture, loop/zone plan and number of devices are clarified. Then technical specifications, cable cross-section/voltage drop calculations, fire scenario and the offer is shared together. Installation, commissioning and testing & commissioning The steps are completed with documentation ready for the official acceptance process.

EN54is a set of standards that define the performance of fire detection and alarm components in Europe. EN54-2, EN54-4 sections such as fire panel regulates functions, power sources and system behavior. EN54 compliant fire alarm systems, reduces false alarms, ensures reliability and Regulation on the Protection of Buildings from Fire Netko Fire facilitates project acceptance, from device selection to field testing. EN54 focused installation performs.

Cost; building size, addressed/conventional preference, number of devices (smoke/heat detector, button, siren-flasher), cable length, fire panel capacity and integration (BMS, CCTV, emergency announcement, gas detection) is shaped according to your needs. Long horizontal lines, which are common in hotel/residence projects in Alanya, affect cable and labor costs. Netko Fire, with transparent pens and alternative configurations scalable pricing avoiding unnecessary equipment return on investment aims to increase.

The time required for procurement, cabling, and installation after project approval depends on the area size and working hours; while boutique establishments can be completed in a few days, multi-story hotels/shopping malls can take weeks. Netko Fire, phased assembly and night/off-hour work schedules with minimal impact on operations. At the end of the installation put in to use, device labeling, fire panel programming and user training are provided.

Fire detection These systems are not "set it and forget it" systems; dust, temperature, humidity and usage changes affect detection performance. Monthly/quarterly/semi-annual according to EN54 and local regulations periodic maintenance recommended. Netko Fire, detector calibration, battery test/replacement, loop/zone continuity control, siren-flasher sound/light level measurement, software update and log analysis comprehensive maintenance report (includinglogbook) produces; thus early warning And rapid evacuation abilities are constantly maintained.

Yes. Conventional infrastructure gradually addressed can carry it to architecture, gas detection, emergency guidance/lighting and BMS–CCTV–emergency announcement We can integrate them. This way, we can perform event monitoring, automatic scenario triggering and reportable business Netko Fire utilizes the existing cabling to the maximum extent in transition projects. cost/efficiency maintains its balance.

Placing the right detector type (optical smoke, heat, multisensor) in the right area, taking into account ventilation and steam sources, installation height and addressed algorithms Significantly reduces false alarms. Netko Fire, detector sensitivity curves, delay/pre-alarm thresholds and fire scenario Optimizes parameters within the scope of the project. Regular periodic maintenance and user training also play a role in reducing false alarms.

Netko Fire, in addition to the manufacturer's warranties, SLA intervention And 24/7 malfunction reporting can provide support. Spare equipment management by scope, for critical areas proactive parts replacement and expedited visit plans are implemented. All service operations and EN54 maintenance steps are reported; thus, in hotels, shopping malls and industrial facilities uninterrupted operation the target is protected.

In the commissioning process device-based addressing, short circuit/earth leakage control, smoke/heat test, siren-flasher verification, scenario simulations and fire panel The incident records are reviewed. The minutes, drawings and other necessary documents for acceptance are collected. as-built Documents are prepared. In the final stage, operator training, emergency procedures and periodic maintenance plan is delivered; a sustainable facility in your Alanya facility fire alarm system operation is provided.